- grot
Device: Grating Rotator
Function: setting grating angle to select wavelength range, or to move
grating rotator to grating exchange position.
- gratID
Device: Grating ID
Function: ID code for each grating. Bit code which is read through magnetic
sensors (update only in grating exchange position).
- col
Device: Fiber spectrograph collimator focus.
Function: moving focussing stage of FSPEC collimator lens.
- cam
Device: Fiber spectrograph camera focus.
Function: moving focussing stage of FSPEC camera lens.
- agfil
Device: A&G Camera Filter
Function: selecting 1 out of 4 A&G Camera filter positions.
Note: Status Window
entry AG FILTER = "none" indicates that filter stage has been moved to an
arbitrary position, i.e. different from any of the 4 locked filter
positions.
- agfoc
Device: A&G Camera focus.
Function: moving focussing stage of A&G camera lens.
- tmtop
Device: Dual linear stage: (1) A&G Camera Optics (AGOPTICS),
and (2) Calibration Unit (CALUNIT)
Function: moving either A&G Camera Pick-off Mirror + optical system,
or Calibration Unit into telescope beam.
- tmtopAg : moves AGOPTICS into the beam
- tmtopCal : moves CALUNIT into the beam
- tmtopPark : moves both AGOPTICS and CALUNIT
into park positions, i.e. out of the beam
- xlmpPow
Device: Calibration Lamp Power Supplies
Function: Switch power supplies on/off; switch between two lamps
sharing the same power supply (x=c,l)
- clmpPow1 : switch continuum lamp power supply
on/off
- llmpPow1 : switch spectral line lamp power supply
1 on/off
- llmp1_2 : select between llmp1 and llmp2 for
llmpPow1
- llmpPow2 : switch spectral line lamp power supply
2 on/off
- llmp1_2 : select between llmp3 and llmp3 for
llmpPow2
- llmpPow3 : switch spectral line lamp power supply
3 on/off
- xsh
Device: Calibration Lamp Shutters
Function: open/close Calibration Lamp Shutters
(x = c1, l1, l2, l3, l4, l5)
- shc1 : open/close continuum lamp shutter
- shl1 : open/close spectral line lamp 1 shutter
- shl2 : open/close spectral line lamp 2 shutter
- shl3 : open/close spectral line lamp 3 shutter
- shl4 : open/close spectral line lamp 4 shutter
- shl5 : open/close spectral line lamp 5 shutter
- calsboxStatus
Device: status of calibration lamps (read-only)
Function: test status of calibration lamps, i.e. illumination=on/off
- shx
Device: shutters
Function: open/close shutters (x = 1, 2, 3, 4)
- sh1 : open/close shutter 1
- sh2 : open/close shutter 2
- sh3 : open/close shutter 3
- sh4 : open/close shutter 4
- tsens
Device: temperature sensors
Function: measure temperature for sensors 1...6
- larrViewLmpx
Device: internal illumination of lensarray viewing system
Function: switch on/off illumination (x=1,2,3) for alignment of lensarray
- limeval
Device: hard limit switch relays
Function: reset hard limit switches
|
|
|