PMAS Status Window: a mechanical device does not reach a valid end position.
The corresponding error flag switches to RED.
-
The error condition is a complex function of VME motor controller parameters.
It could be as simple as the timeout of a somewhat worn-out gear, requiring a
longer positioning period than foreseen originally. On the other hand, it
could be a serious mechanical or electronic failure, which might potentially
cause a catastrophic failure of some sort (collision of mechanical stages,
limit switch overrun, etc.
-
Reset and re-initialize the affected component.
Note: ONLY TO BE DONE BY CAHA STAFF
-
On rike xterm, type (e.g. for collimator focus motor) :
rike:colReset
rike:colInit
Verify, that error condition has been solved:
rike:colStatus
-
Reset/Init scripts are available for the following devices :
Spectrograph Collimator Focus :
colReset
colInit
colStatus
Spectrograph Camera Focus :
camReset
camInit
camStatus
grotReset
grotInit
grotStatus
foReset
foInit
foStatus
A&G Camera and Calibration Unit exchange mechanism :
tmtopReset
tmtopInit
tmtopStatus
A&G Camera Filter exchange mechanism:
agfilReset
agfilInit
agfilStatus
agfocReset
agfocInit
agfocStatus
-
If an error persists despite reset, try :
limevalSet