Red error flag "AG FILTER ERROR" in PMAS Status Window.
-
The VME motor controller has experienced an error condition of the A&G Camera
filter stage. The error may be related to a hardware problem, a software
problem , or to a spurious error condition. If the error is prevailing despite
the solution advised below, a more serious hardware failure must be suspected.
Consult support for advice.
agfilReset
limevalSet
agfilInit
agfilStatus
After agfilStatus, the following message should appear: TBD.
If the LOCKED status is not reached, reset the vme controller lea
(reset button on lea frontpanel - do not confuse with abort button !)
Repeat the sequence from above. If there is no success, call support.
Note: It is possible to dismount the AG camera filter stage and
carefully rotate the translation spindle by hand. One can thus
move a certain filter into the optical path and continue operation.
Alternatively, switch to the standard 3.5m TV Guider system:
pics_gui pulldown menu: SetMode -> Guiding -> External TV Guider